arm: tegra: pluto: modify sensor slave address
Shantanu Nath [Fri, 14 Sep 2012 14:32:50 +0000 (19:32 +0530)]
imx091 and imx132 have same slave address and they are on same bus.
However device manufacturer has provided option to pick from
different slave address. So changing the address for imx091.

Bug 961418

Change-Id: Ibbbd396b0ed19a1f318029c6c3e0cf0339797eb3
Signed-off-by: Shantanu Nath <snath@nvidia.com>
Reviewed-on: http://git-master/r/132671
(cherry picked from commit b8a350c6c59321b9c1ff6431b330a074d5e6bfbf)
Reviewed-on: http://git-master/r/133171
Reviewed-by: Automatic_Commit_Validation_User
Reviewed-by: Sachin Nikam <snikam@nvidia.com>
Tested-by: Rohan Somvanshi <rsomvanshi@nvidia.com>

Rebase-Id: R84e5873061d3204bc85ff72a9e3aa638522bfff5

arch/arm/mach-tegra/board-pluto-sensors.c

index bc72036..dfdd742 100644 (file)
@@ -178,7 +178,7 @@ struct imx132_platform_data pluto_imx132_data = {
 
 static struct i2c_board_info pluto_i2c_board_info_e1625[] = {
        {
-               I2C_BOARD_INFO("imx091", 0x36),
+               I2C_BOARD_INFO("imx091", 0x10),
                .platform_data = &pluto_imx091_data,
        },
        {