ARM: tegra: clock: Change default sampling period to 12ms
Tom Cherry [Tue, 5 Jul 2011 22:08:53 +0000 (15:08 -0700)]
Bug 845349

Original-Change-Id: I0ce1a5da9a80cea6a4e55bc92490e6ae8508e22f
Reviewed-on: http://git-master/r/39704
Tested-by: Thomas Cherry <tcherry@nvidia.com>
Reviewed-by: Aleksandr Frid <afrid@nvidia.com>
Reviewed-by: Bharat Nihalani <bnihalani@nvidia.com>

Rebase-Id: Rfc2bfc89082778e43d15406b0b5e53bdf845f08e

arch/arm/mach-tegra/tegra3_actmon.c

index 4aebd75..c4a513d 100644 (file)
@@ -80,7 +80,7 @@ enum actmon_state {
        ACTMON_SUSPENDED = 2,
 };
 
-#define ACTMON_DEFAULT_SAMPLING_PERIOD         10
+#define ACTMON_DEFAULT_SAMPLING_PERIOD         12
 static u8 actmon_sampling_period;
 
 static unsigned long actmon_clk_freq;