ARM: tegra: enterprise: Remove external control for touchscreen
Xiaohui Tao [Mon, 12 Nov 2012 18:17:11 +0000 (10:17 -0800)]
Atmel chip need to be resetted after waking up from LP0.
Enterprise A03 LDO7 needs to be controlled by software so
that the regulator notifier gets called when it wakes up from
LP0. Remove the external control for Enterprise A03 LDO7.

Bug 1163642

Change-Id: Iabe9b87e91449bd6f6437929c5e76058b41c08e8
Signed-off-by: Xiaohui Tao <xtao@nvidia.com>
Reviewed-on: http://git-master/r/163062
Reviewed-by: Automatic_Commit_Validation_User
Reviewed-by: Robert Collins <rcollins@nvidia.com>
Reviewed-by: Thomas Cherry <tcherry@nvidia.com>

arch/arm/mach-tegra/board-enterprise-power.c

index 16dea10..6ee7cef 100644 (file)
@@ -315,7 +315,7 @@ TPS_PDATA_INIT(LDO5, ldo5, a03, 1000, 3300, 0, 0, 0, 0, -1, 0, 0, 0, 0, 0);
 TPS_PDATA_INIT(LDO6, ldo6, a02, 1000, 3300, 0, 0, 0, 0, -1, 0, 0, 0, PWR_REQ_INPUT_PREQ1, 0);
 TPS_PDATA_INIT(LDO6, ldo6, a03, 1000, 3300, 0, 0, 0, 0, -1, 0, 0, 0, PWR_REQ_INPUT_PREQ1, 0);
 TPS_PDATA_INIT(LDO7, ldo7, a02, 1000, 3300, tps80031_rails(vio), 0, 0, 0, -1, 0, 0, 0, PWR_REQ_INPUT_PREQ1, 0);
-TPS_PDATA_INIT(LDO7, ldo7, a03, 1000, 3300, 0, 0, 0, 0, -1, 0, 0, 0, PWR_REQ_INPUT_PREQ1, 0);
+TPS_PDATA_INIT(LDO7, ldo7, a03, 1000, 3300, 0, 0, 0, 0, -1, 0, 0, 0, 0, 0);
 TPS_PDATA_INIT(LDOLN, ldoln, a02, 1000, 3300, tps80031_rails(smps3), 0, 0, 0, -1, 0, 0, 0, PWR_REQ_INPUT_PREQ1, 0);
 TPS_PDATA_INIT(LDOLN, ldoln, a03, 1000, 3300, tps80031_rails(vio), 0, 0, 0, -1, 0, 0, 0, PWR_REQ_INPUT_PREQ1, 0);
 TPS_PDATA_INIT(LDOUSB, ldousb, a02, 1000, 3300, 0, 0, 0, 0, -1, 0, 0, USBLDO_INPUT_VSYS, PWR_OFF_ON_SLEEP, 0);