md: Factor out RAID6 algorithms into lib/
[linux-2.6.git] / drivers / md / Kconfig
1 #
2 # Block device driver configuration
3 #
4
5 menuconfig MD
6         bool "Multiple devices driver support (RAID and LVM)"
7         depends on BLOCK
8         help
9           Support multiple physical spindles through a single logical device.
10           Required for RAID and logical volume management.
11
12 if MD
13
14 config BLK_DEV_MD
15         tristate "RAID support"
16         ---help---
17           This driver lets you combine several hard disk partitions into one
18           logical block device. This can be used to simply append one
19           partition to another one or to combine several redundant hard disks
20           into a RAID1/4/5 device so as to provide protection against hard
21           disk failures. This is called "Software RAID" since the combining of
22           the partitions is done by the kernel. "Hardware RAID" means that the
23           combining is done by a dedicated controller; if you have such a
24           controller, you do not need to say Y here.
25
26           More information about Software RAID on Linux is contained in the
27           Software RAID mini-HOWTO, available from
28           <http://www.tldp.org/docs.html#howto>. There you will also learn
29           where to get the supporting user space utilities raidtools.
30
31           If unsure, say N.
32
33 config MD_AUTODETECT
34         bool "Autodetect RAID arrays during kernel boot"
35         depends on BLK_DEV_MD=y
36         default y
37         ---help---
38           If you say Y here, then the kernel will try to autodetect raid
39           arrays as part of its boot process. 
40
41           If you don't use raid and say Y, this autodetection can cause 
42           a several-second delay in the boot time due to various
43           synchronisation steps that are part of this step.
44
45           If unsure, say Y.
46
47 config MD_LINEAR
48         tristate "Linear (append) mode"
49         depends on BLK_DEV_MD
50         ---help---
51           If you say Y here, then your multiple devices driver will be able to
52           use the so-called linear mode, i.e. it will combine the hard disk
53           partitions by simply appending one to the other.
54
55           To compile this as a module, choose M here: the module
56           will be called linear.
57
58           If unsure, say Y.
59
60 config MD_RAID0
61         tristate "RAID-0 (striping) mode"
62         depends on BLK_DEV_MD
63         ---help---
64           If you say Y here, then your multiple devices driver will be able to
65           use the so-called raid0 mode, i.e. it will combine the hard disk
66           partitions into one logical device in such a fashion as to fill them
67           up evenly, one chunk here and one chunk there. This will increase
68           the throughput rate if the partitions reside on distinct disks.
69
70           Information about Software RAID on Linux is contained in the
71           Software-RAID mini-HOWTO, available from
72           <http://www.tldp.org/docs.html#howto>. There you will also
73           learn where to get the supporting user space utilities raidtools.
74
75           To compile this as a module, choose M here: the module
76           will be called raid0.
77
78           If unsure, say Y.
79
80 config MD_RAID1
81         tristate "RAID-1 (mirroring) mode"
82         depends on BLK_DEV_MD
83         ---help---
84           A RAID-1 set consists of several disk drives which are exact copies
85           of each other.  In the event of a mirror failure, the RAID driver
86           will continue to use the operational mirrors in the set, providing
87           an error free MD (multiple device) to the higher levels of the
88           kernel.  In a set with N drives, the available space is the capacity
89           of a single drive, and the set protects against a failure of (N - 1)
90           drives.
91
92           Information about Software RAID on Linux is contained in the
93           Software-RAID mini-HOWTO, available from
94           <http://www.tldp.org/docs.html#howto>.  There you will also
95           learn where to get the supporting user space utilities raidtools.
96
97           If you want to use such a RAID-1 set, say Y.  To compile this code
98           as a module, choose M here: the module will be called raid1.
99
100           If unsure, say Y.
101
102 config MD_RAID10
103         tristate "RAID-10 (mirrored striping) mode (EXPERIMENTAL)"
104         depends on BLK_DEV_MD && EXPERIMENTAL
105         ---help---
106           RAID-10 provides a combination of striping (RAID-0) and
107           mirroring (RAID-1) with easier configuration and more flexible
108           layout.
109           Unlike RAID-0, but like RAID-1, RAID-10 requires all devices to
110           be the same size (or at least, only as much as the smallest device
111           will be used).
112           RAID-10 provides a variety of layouts that provide different levels
113           of redundancy and performance.
114
115           RAID-10 requires mdadm-1.7.0 or later, available at:
116
117           ftp://ftp.kernel.org/pub/linux/utils/raid/mdadm/
118
119           If unsure, say Y.
120
121 config MD_RAID456
122         tristate "RAID-4/RAID-5/RAID-6 mode"
123         depends on BLK_DEV_MD
124         select RAID6_PQ
125         select ASYNC_MEMCPY
126         select ASYNC_XOR
127         select ASYNC_PQ
128         select ASYNC_RAID6_RECOV
129         ---help---
130           A RAID-5 set of N drives with a capacity of C MB per drive provides
131           the capacity of C * (N - 1) MB, and protects against a failure
132           of a single drive. For a given sector (row) number, (N - 1) drives
133           contain data sectors, and one drive contains the parity protection.
134           For a RAID-4 set, the parity blocks are present on a single drive,
135           while a RAID-5 set distributes the parity across the drives in one
136           of the available parity distribution methods.
137
138           A RAID-6 set of N drives with a capacity of C MB per drive
139           provides the capacity of C * (N - 2) MB, and protects
140           against a failure of any two drives. For a given sector
141           (row) number, (N - 2) drives contain data sectors, and two
142           drives contains two independent redundancy syndromes.  Like
143           RAID-5, RAID-6 distributes the syndromes across the drives
144           in one of the available parity distribution methods.
145
146           Information about Software RAID on Linux is contained in the
147           Software-RAID mini-HOWTO, available from
148           <http://www.tldp.org/docs.html#howto>. There you will also
149           learn where to get the supporting user space utilities raidtools.
150
151           If you want to use such a RAID-4/RAID-5/RAID-6 set, say Y.  To
152           compile this code as a module, choose M here: the module
153           will be called raid456.
154
155           If unsure, say Y.
156
157 config MULTICORE_RAID456
158         bool "RAID-4/RAID-5/RAID-6 Multicore processing (EXPERIMENTAL)"
159         depends on MD_RAID456
160         depends on SMP
161         depends on EXPERIMENTAL
162         ---help---
163           Enable the raid456 module to dispatch per-stripe raid operations to a
164           thread pool.
165
166           If unsure, say N.
167
168 config ASYNC_RAID6_TEST
169         tristate "Self test for hardware accelerated raid6 recovery"
170         depends on RAID6_PQ
171         select ASYNC_RAID6_RECOV
172         ---help---
173           This is a one-shot self test that permutes through the
174           recovery of all the possible two disk failure scenarios for a
175           N-disk array.  Recovery is performed with the asynchronous
176           raid6 recovery routines, and will optionally use an offload
177           engine if one is available.
178
179           If unsure, say N.
180
181 config MD_MULTIPATH
182         tristate "Multipath I/O support"
183         depends on BLK_DEV_MD
184         help
185           Multipath-IO is the ability of certain devices to address the same
186           physical disk over multiple 'IO paths'. The code ensures that such
187           paths can be defined and handled at runtime, and ensures that a
188           transparent failover to the backup path(s) happens if a IO errors
189           arrives on the primary path.
190
191           If unsure, say N.
192
193 config MD_FAULTY
194         tristate "Faulty test module for MD"
195         depends on BLK_DEV_MD
196         help
197           The "faulty" module allows for a block device that occasionally returns
198           read or write errors.  It is useful for testing.
199
200           In unsure, say N.
201
202 config BLK_DEV_DM
203         tristate "Device mapper support"
204         ---help---
205           Device-mapper is a low level volume manager.  It works by allowing
206           people to specify mappings for ranges of logical sectors.  Various
207           mapping types are available, in addition people may write their own
208           modules containing custom mappings if they wish.
209
210           Higher level volume managers such as LVM2 use this driver.
211
212           To compile this as a module, choose M here: the module will be
213           called dm-mod.
214
215           If unsure, say N.
216
217 config DM_DEBUG
218         boolean "Device mapper debugging support"
219         depends on BLK_DEV_DM
220         ---help---
221           Enable this for messages that may help debug device-mapper problems.
222
223           If unsure, say N.
224
225 config DM_CRYPT
226         tristate "Crypt target support"
227         depends on BLK_DEV_DM
228         select CRYPTO
229         select CRYPTO_CBC
230         ---help---
231           This device-mapper target allows you to create a device that
232           transparently encrypts the data on it. You'll need to activate
233           the ciphers you're going to use in the cryptoapi configuration.
234
235           Information on how to use dm-crypt can be found on
236
237           <http://www.saout.de/misc/dm-crypt/>
238
239           To compile this code as a module, choose M here: the module will
240           be called dm-crypt.
241
242           If unsure, say N.
243
244 config DM_SNAPSHOT
245        tristate "Snapshot target"
246        depends on BLK_DEV_DM
247        ---help---
248          Allow volume managers to take writable snapshots of a device.
249
250 config DM_MIRROR
251        tristate "Mirror target"
252        depends on BLK_DEV_DM
253        ---help---
254          Allow volume managers to mirror logical volumes, also
255          needed for live data migration tools such as 'pvmove'.
256
257 config DM_LOG_USERSPACE
258         tristate "Mirror userspace logging (EXPERIMENTAL)"
259         depends on DM_MIRROR && EXPERIMENTAL && NET
260         select CONNECTOR
261         ---help---
262           The userspace logging module provides a mechanism for
263           relaying the dm-dirty-log API to userspace.  Log designs
264           which are more suited to userspace implementation (e.g.
265           shared storage logs) or experimental logs can be implemented
266           by leveraging this framework.
267
268 config DM_ZERO
269         tristate "Zero target"
270         depends on BLK_DEV_DM
271         ---help---
272           A target that discards writes, and returns all zeroes for
273           reads.  Useful in some recovery situations.
274
275 config DM_MULTIPATH
276         tristate "Multipath target"
277         depends on BLK_DEV_DM
278         # nasty syntax but means make DM_MULTIPATH independent
279         # of SCSI_DH if the latter isn't defined but if
280         # it is, DM_MULTIPATH must depend on it.  We get a build
281         # error if SCSI_DH=m and DM_MULTIPATH=y
282         depends on SCSI_DH || !SCSI_DH
283         ---help---
284           Allow volume managers to support multipath hardware.
285
286 config DM_MULTIPATH_QL
287         tristate "I/O Path Selector based on the number of in-flight I/Os"
288         depends on DM_MULTIPATH
289         ---help---
290           This path selector is a dynamic load balancer which selects
291           the path with the least number of in-flight I/Os.
292
293           If unsure, say N.
294
295 config DM_MULTIPATH_ST
296         tristate "I/O Path Selector based on the service time"
297         depends on DM_MULTIPATH
298         ---help---
299           This path selector is a dynamic load balancer which selects
300           the path expected to complete the incoming I/O in the shortest
301           time.
302
303           If unsure, say N.
304
305 config DM_DELAY
306         tristate "I/O delaying target (EXPERIMENTAL)"
307         depends on BLK_DEV_DM && EXPERIMENTAL
308         ---help---
309         A target that delays reads and/or writes and can send
310         them to different devices.  Useful for testing.
311
312         If unsure, say N.
313
314 config DM_UEVENT
315         bool "DM uevents (EXPERIMENTAL)"
316         depends on BLK_DEV_DM && EXPERIMENTAL
317         ---help---
318         Generate udev events for DM events.
319
320 endif # MD